Rorke Data The Galaxy 65 Spezifikationen Seite 62

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 100
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 61
Galaxy GHDX-2422S-8+12F4D Installation and Hardware Reference Manual
Power On
4-6
4.2 Power On
Once all the components have been installed in the Galaxy subsystem, the host channels
have been connected to the host, power on the FC networking devices (e.g., FC switches),
the subsystem, and then power on the host computer(s).
4.2.1 Check List
BEFORE powering on the Galaxy subsystem, please check the following:
Memory Modules – Memory modules have been correctly installed on the
controller boards.
BBU Modules – If used, that the BBU modules have been installed correctly.
Hard Drives – Hard drives have been correctly installed on the drive trays.
Drive TraysALL the drive trays, whether or not they have a hard drive, have
been installed into the subsystem.
Cable Connections – The host ports on the subsystem have been correctly
connected to a host computer.
Power Cables – The power cables have been connected to the PSU modules on
the subsystem and plugged into main power.
Ambient Temperature – All the subsystem components have been acclimated to
the surrounding temperature.
4.2.2 Power On Procedure
When powering on the Galaxy subsystem, please follow these steps.
1. Power on the Fibre Channel networking devices.
These devices include the FC switches, and any other such device that have been
connected to the subsystem. Please refer to the documentation that came with your
FC devices to see the power on procedure.
2. Power on the subsystem.
The subsystem should only be powered on after all the Fibre Channel connection
devices have been powered on first. The subsystem power on procedure is described
below.
Seitenansicht 61